2) Slide the No. 1 mirror base [1] to the right to match
it against the cut off [2] of the frame.
When sliding the No. 1 mirror base, be sure to
hold it by the cut up tab [A] of the mirror stay.
[1]
[2]
F-5-53
4) Remove the 2 screws [1], and detach the scanning
lamp [2].
[1]
[2]
F-5-54
[2]
[A]
[1]
5.4.3 Reader Controller PCB
5.4.3.1 Removing the
Copyboard Glass
1) Open the ADF.
2) Remove the 2 screws [1], and detach the right glass
retainer [2]; then, detach the copyboard glass [3].
[3]
F-5-55
When detaching the copyboard glass, take care not
to touch the white plate attached to its back. (Soiling
can cause lines in the image). If soiled, clean it using
lint free paper moistened with alcohol.)
5.4.3.2 Removing the CCD
Unit Cover
1) Remove the 9 screws [1], and detach the CCD unit
cover [2].
[1]
F-5-56
Chapter 5
0003-3123
[1]
[2]
0003-3145
[1]
[2]
5-27