Lldp Reinit - Dell PowerConnect PC5524 Reference Manual

5500 series
Table of Contents

Advertisement

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax
TTL = min(65535, LLDP-Timer * LLDP-HoldMultiplier)
For example, if the value of the LLDP timer is 30 seconds, and the value of
the LLDP hold multiplier is 4, then the value 120 is encoded in the TTL field
of the LLDP header.
Example
The following example sets the LLDP packet hold time interval to 90
seconds.
Console(config)#
Console(config)#

lldp reinit

Use the lldp reinit Global Configuration mode command to specify the
minimum time an LLDP port waits before reinitializing LLDP transmission.
Use the no form of this command to revert to the default setting.
Syntax
lldp reinit seconds
no lldp reinit
Parameters
seconds—Specifies the minimum time in seconds an LLDP port waits before
reinitializing LLDP transmission.(Range: 1–10)
Default
2 seconds
Command Mode
Global Configuration mode
Example
console(config)# lldp reinit 4
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 5 / 1 5 / 1 2 - F O R P R O O F O N LY
CLI\files\LLDP.fm
30
lldp timer
lldp hold-multiplier
3
LLDP Commands
427