show chassis-status

Every two seconds, a blade broadcasts heartbeat messages. A state table on the supervisor
and each blade tracks every unit in the chassis. The table maintains a running history of the
heartbeat messages, current observed interval, and the minimum, maximum, and average
observed times between heartbeat messages. Sequence numbers in the discovery
messaged determine loss.
Format
chassis-status unit [unit | all] [clear]
Mode
User EXEC
Command example:
(NETGEAR Switch) #show chassis-status 1
Chassis Unit 1 Status
Unit
Current
Average
1
2000
2000
2
2000
2100
3
2000
2100

show supported switchtype

This commands displays information about all supported switch types or a specific switch
type.
Format
show supported switchtype [switchindex]
Mode
User EXEC
Privileged EXEC
If you do not supply a value for switchindex, the following output appears:
Term
Definition
Switch Index (SID)
The index into the database of supported blade types. This index is used when you
preconfigure a member to be added to the chassis.
Model Identifier
The model identifier for the supported blade type.
Management
The management preference value of the blade type.
Preference
Code Version
The code load target identifier of the blade type.
M6100 Series Switches
Min
Max
Dropped
2000
2000
0
2000
2500
0
2000
2200
0
Chassis Commands