Environment Trap; Debug Environment - NETGEAR M6100 Series Reference Manual

Hide thumbs Also See for M6100 Series:
Table of Contents

Advertisement

Parameter
Definition
min temperature
Sets the minimum allowed temperature for normal operation. The range is between
– 100°C and 100°C. The default is 0°C.
max temperature
Sets the maximum allowed temperature for normal operation. The range is between
– 100°C and 100°C. The default is 0°C.

environment trap

Use this command to configure environment status traps.
Format
environment trap {fan | powersupply | temperature}
Mode
Global Config
Parameter
Definition
fan
Enables or disables the sending of traps for fan status events. The default is enable.
powersupply
Enables or disables the sending of traps for power supply status events. The default is enable.
temperature
Enables or disables the sending of traps for temperature status events. The default is enable.

debug environment

This command displays the error logs, including information such as zero temperature
reading, number of resets, and power module failures on the switch since the last time it was
rebooted.
Note:
To display the debug trace, enable the
Format
debug environment
Mode
Privileged EXEC
Command example:
(NETGEAR Switch) #debug environment
Temperature Sensors:
Slot Sensor id # of Reset
1
1
2
1
3
1
Power supplies:
Module Failures
------ --------
1
0
2
0
3
0
M6100 Series Switches
debug console
0
1
0
Utility Commands
180
command.