Power System - NETGEAR M6100 Series Reference Manual

Hide thumbs Also See for M6100 Series:
Table of Contents

Advertisement

Default
Disabled
Format
power redundancy
Mode
Chassis Global Config
Note:
If the total available power minus the total consumed power is less
than what one PSU can supply, the switch does not enable the N+1
feature. Instead, it generates the following error message on the
console and in the logging buffer:
Not enough power to enable N+1 feature. Total
available power: <X>. Total consumption power: <Y>
no power redundancy
This command disables the N+1 power redundancy feature.
Format
no power redundancy
Mode
Chassis Global Config

power system

This command configures the total chassis system power (12V power) for the base blades.
Default
110W per blade
Format
power system 12v_power
Mode
Chassis Global Config
Note:
The switch compares the value that you enter with the total required
system power. If the value that you enter is too low, the switch
generates the following message before executing the command:
Warning: setting system power system power may cause
blade or PoE ports to shut down. Are you sure you
want to continue? (y/n):
If you enter y, the system power is updated as requested; Otherwise,
the system power is not updated.
M6100 Series Switches
Utility Commands
274

Advertisement

Table of Contents
loading

Table of Contents