Description
Receiver Owner
The identity string for the receiver, the entity making use of this sFlowRcvrTable entry. The range is
127 characters. The default is a null string. The empty string indicates that the entry is currently
unclaimed and the receiver configuration is reset to the default values. An entity wishing to claim an
sFlowRcvrTable entry must ensure that the entry is unclaimed before trying to claim it. The entry is
claimed by setting the owner string to a non-null value. The entry must be claimed before assigning
a receiver to a sampler or poller.
Receiver Timeout
The time, in seconds, remaining before the sampler or poller is released and stops sending samples
to receiver. A management entity wanting to maintain control of the sampler is responsible for setting
a new value before the old one expires. The allowed range is 0-2147483647 seconds. The default is
zero (0).
No Timeout
The configured entry will be in the config until you explicitly removes the entry.
Receiver Max
The maximum number of data bytes that can be sent in a single sample datagram. The
Datagram Size
management entity should set this value to avoid fragmentation of the sFlow datagrams. The
allowed range is 200 to 9116). The default is 1400.
Receiver IP
The sFlow receiver IP address. If set to 0.0.0.0, no sFlow datagrams will be sent. The default is
0.0.0.0.
Receiver Port
The destination Layer4 UDP port for sFlow datagrams. The range is 1-65535. The default is 6343.
no sflow receiver
Use this command to set the sFlow collector parameters back to the defaults.
Format
no sflow receiver indx {ip ipaddress | maxdatagram size | owner string
timeout interval | port number}
Mode
Global Config

sflow receiver owner timeout

Use this command to configure a receiver as a timeout entry. As the sFlow receiver is
configured as a timeout entry, information related to sampler and pollers are also shown in
the running-config and are retained after reboot.
If a receiver is configured with a specific value, these configurations are not shown in the
running-config file. Samplers and pollers information related to this receiver are also not
shown in the running-config file.
Format
sflow receiver index owner owner-string timeout
Mode
Global Config