Mbus Client Exec - THOMSON ST780 WL Cli Reference Manual

Hide thumbs Also See for ST780 WL:
Table of Contents

Advertisement

MBUS Commands

mbus client exec

Execute mbus command.
SYNTAX:
mbus client exec
where:
cmd
param
value
gettype
depth
processcmd
readcommitted
onerrorrollback
E-DOC-CTC-20061027-0012 v2.0
cmd = <{addobject | deleteobject | getparamattributes
| getparamcount | getparamnames | getparamvalues |
getpath | setparamvalue}>
[param = <quoted string>]
[value = <quoted string>]
[gettype = <{object | parameter | path}>]
[depth = <number>]
[processcmd = <{disabled | enabled}>]
[readcommitted = <{disabled | enabled}>]
[onerrorrollback = <{disabled | enabled}>]
Mbus command name.
Choose between:
>
addobject
>
deleteobject
>
getparamattributes
>
getparamcount
>
getparamnames
>
getparamvalues
>
getpath
>
setparamvalue
Parameter name.
Parameter value to set.
Get type elements.
Choose between:
>
object
>
parameter
>
path
The default is parameter.
Number of levels to recurse, default=-1 (all).
Enable or disable the process SET_PARAMVALUE
command flag.
The default is enabled.
Enable or disable the read committed data only
(MBUS_CMD_GET_PARAMVALUES) flag.
The default is enabled.
Enable or disable the on error rollback flag.
The default is enabled.
REQUIRED
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
521