Parameters
List of Parameters
r0197
Bootloader vers / Bootloader vers
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the bootloader version.
Dependency:
Refer to: r0018, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0198[0...1]
BIOS/EEPROM data version / BIOS/EEPROM vers
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the BIOS and EEPROM data version.
r0198[0]: BIOS version
r0198[1]: EEPROM data version
Dependency:
Refer to: r0018, r0197
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
p0199[0...24]
Drive object name / DO name
Access level: 4
Can be changed: C
Units group: -
Min
0
Description:
Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configura-
tion assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
Note:
The parameter is not influenced by setting the factory setting.
r0200[0...n]
Power unit code number actual / PU code no. act
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the unique code number of the power unit.
Note:
r0200 = 0: No power unit data found
1-42
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
-
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: Unsigned32
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
-
Data type: Unsigned16
Data set: -
Factory setting
0
Data type: Unsigned16
Data set: PDS
Factory setting
-