Parameters
List of Parameters
p3324[0...n]
Fluid flow machine P = f(n), Y coordinate: P flow3 %, point 3 / Fluid flow mach Y3
Access level: 2
Can be changed: U, T
Units group: -
Min
0.00
Description:
The power (P) for point 3 on the Y coordinate of the flow characteristic is saved in p3324. Unit: %
Dependency:
Refer to: p3325
Note:
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
p3325[0...n]
Fluid flow machine P = f(n), X coordinate: n flow3 %, point 3 / Fluid flow mach X3
Access level: 2
Can be changed: U, T
Units group: -
Min
0.00
Description:
The speed (n) for point 3 on the X coordinate of the flow characteristic is saved in p3325. Unit: %
Dependency:
Refer to: p3324
Note:
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
p3326[0...n]
Fluid flow machine P = f(n), Y coordinate: P flow4 %, point 4 / Fluid flow mach Y4
Access level: 2
Can be changed: U, T
Units group: -
Min
0.00
Description:
The power (P) for point 4 on the Y coordinate of the flow characteristic is saved in p3326. Unit: %
Dependency:
Refer to: p3327
Note:
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
p3327[0...n]
Fluid flow machine P = f(n), X coordinate: n flow4 %, point 4 / Fluid flow mach X4
Access level: 2
Can be changed: U, T
Units group: -
Min
0.00
Description:
The speed (n) for point 4 on the X coordinate of the flow characteristic is saved in p3327. Unit: %
Dependency:
Refer to: p3326
Note:
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
1-326
Calculated: -
Scaling: -
Unit selection: -
Max
100.00
Calculated: -
Scaling: -
Unit selection: -
Max
100.00
Calculated: -
Scaling: -
Unit selection: -
Max
100.00
Calculated: -
Scaling: -
Unit selection: -
Max
100.00
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
77.00
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
50.00
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
92.00
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
75.00
© Siemens AG 2011 All Rights Reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu230p-2

Table of Contents