p1001[0...n]
CO: Fixed speed setpoint 1 / n_set_fixed 1
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 1.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1002[0...n]
CO: Fixed speed setpoint 2 / n_set_fixed 2
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 2.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1003[0...n]
CO: Fixed speed setpoint 3 / n_set_fixed 3
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 3.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1004[0...n]
CO: Fixed speed setpoint 4 / n_set_fixed 4
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 4.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1005[0...n]
CO: Fixed speed setpoint 5 / n_set_fixed 5
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 5.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
1-125