Parameters
List of Parameters
p0970
Reset drive parameters / Drive par reset
Access level: 1
Can be changed: C(1, 30)
Units group: -
Min
0
Description:
The parameter is used to initiate the reset of the drive parameters.
Parameters p0100, p0205 are not reset.
The following motor parameters are defined in accordance with the power unit: p0300 ... p0311.
When downloading settings 10, 11, 12, the buffer memory mode is automatically deactivated (p0014 = 0).
Value:
0:
1:
10:
11:
12:
100:
300:
Caution:
When the buffer memory is active (see p0014), the actual parameters are backed up from RAM to ROM when a
parameter set is loaded (p0970 = 10, 11, 12).
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Peculiarities of communication via PROFIBUS DP:
- Communication with Class 1 masters (e.g. S7 controllers) is interrupted.
- Communication with Class 2 masters (e.g. STARTER) is retained.
Note:
A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
Parameter reset has been completed if p0970 and p0010 have been set to 0.
The following generally applies:
One index of parameters p2100, p2101, p2118, p2119, p2126, p2127 is not reset, if a parameterized message is
precisely active in this index.
p0971
Save parameters / Save par
Access level: 1
Can be changed: U, T
Units group: -
Min
0
Description:
Setting to save parameters in the non-volatile memory.
Value:
0:
1:
10:
11:
12:
Dependency:
Refer to: p1960, r3996
Caution:
If a memory card (optional) is inserted, the following applies:
The parameters are also saved on the card and therefore overwrite any existing data!
Caution:
The Control Unit power supply may only be powered down after data has been saved (i.e. after data save has been
started, wait until the parameter again has the value 0).
Notice:
Writing to parameters is inhibited while saving.
The progress while saving is displayed in r3996.
1-118
Inactive
Start a parameter reset
Starts to download setting 10
Starts to download setting 11
Starts to download setting 12
Start a BICO interconnection reset
Only Siemens internal
Inactive
Save drive object
Save in non-volatile memory as setting 10
Save in non-volatile memory as setting 11
Save in non-volatile memory as setting 12
Calculated: -
Scaling: -
Unit selection: -
Max
300
Calculated: -
Scaling: -
Unit selection: -
Max
12
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: Unsigned16
Data set: -
Factory setting
0
Data type: Unsigned16
Data set: -
Factory setting
0