Parameters
List of Parameters
r1408.0...14
CO/BO: Status word current controller / ZSW I_ctrl
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the current controller status word.
Bit field:
Bit
Signal name
00
Current ctrl act
01
Id control, I component limiting
03
Voltage limiting
10
Speed adaptation, limiting
12
Motor stalled
13
Separately excited synchronous motor is
excited
14
Current model FEM: magnetizing excitation
current limited to 0
p1416[0...n]
Speed setpoint filter 1 time constant / n_set_filt 1 T
Access level: 4
Can be changed: U, T
Units group: -
Min
0.00 [ms]
Description:
Sets the time constant for the speed setpoint filter 1 (PT1).
r1438
CO: Speed controller, speed setpoint / n_ctrl n_set
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the speed setpoint after setpoint limiting for the P component of the speed controller.
For U/f operation, the value that is displayed is of no relevance.
Dependency:
Refer to: r1439
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
r1439
Speed setpoint, I component / n_set I_comp
Access level: 4
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the speed setpoint for the I component of the speed controller (output of the reference model after the set-
point limiting).
Dependency:
Refer to: r1438
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
1-192
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Active
Active
Active
Active
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
5000.00 [ms]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: Unsigned16
Data set: -
Factory setting
-
0 signal
Not active
Not active
Not active
Not active
No
No
No
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.00 [ms]
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
© Siemens AG 2011 All Rights Reserved
FP
-
6714
6714
-
-
-
-