Siemens SINAMICS G120 Manual page 126

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Parameters
List of Parameters
p1006[0...n]
CO: Fixed speed setpoint 6 / n_set_fixed 6
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 6.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1007[0...n]
CO: Fixed speed setpoint 7 / n_set_fixed 7
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 7.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fixed 8
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 8.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fixed 9
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 9.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 10.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
1-126
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]