Parameters
List of Parameters
p1048[0...n]
Motorized potentiometer ramp-down time / Mop ramp-down time
Access level: 2
Can be changed: U, T
Units group: -
Min
0.000 [s]
Description:
Sets the ramp-down time for the internal ramp-function generator for the motorized potentiometer.
The setpoint is changed from the speed/velocity limit (p1082) to zero within this time (if no initial rounding-off has
been activated).
Dependency:
Refer to: p1030, p1047, p1082
Note:
The deceleration time is extended corresponding to the activated initial rounding-off (p1030.2).
r1050
CO: Motor. potentiometer setpoint after the ramp-function generator /
Mop setp after RFG
Access level: 2
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Sets the effective setpoint after the internal motorized potentiometer ramp-function generator.
This setpoint is the output value of the motorized potentiometer and must be appropriately interconnected onwards
(e.g. with the main setpoint).
Dependency:
Refer to: p1070
Note:
For "With ramp-function generator", after an OFF1, OFF2, OFF3 or for a 0 signal via BI: p0852 (inhibit operation,
cancel pulses) the ramp-function generator output (r1050) is set to the starting value (configuration via p1030.0).
p1051[0...n]
CI: Speed limit RFG positive direction of rotation / n_limit RFG pos
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the speed limit of the positive direction on the ramp-function generator input.
p1052[0...n]
CI: Speed limit RFG negative direction of rotation / n_limit RFG neg
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the speed limit of the negative direction on the ramp-function generator input.
1-134
Calculated: -
Scaling: -
Unit selection: -
Max
1000.000 [s]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
10.000 [s]
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
1083[0]
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
1086[0]