Siemens SINAMICS G120 Manual page 297

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

p2215[0...n]
CO: Technology controller, fixed value 15 / Tec_ctr fix val 15
Access level: 2
Can be changed: U, T
Units group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 15 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2216[0...n]
Technology controller fixed value selection method / Tec_ctr FixVal sel
Access level: 2
Can be changed: T
Units group: -
Min
1
Description:
Selects the method that can be used to select the fixed setpoints.
Value:
1:
2:
p2220[0...n]
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2221, p2222, p2223
p2221[0...n]
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2222, p2223
p2222[0...n]
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2221, p2223
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Fixed value selection direct
Fixed value selection binary
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
150.00 [%]
Data type: Integer16
Data set: DDS, p0180
Factory setting
1
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
0
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
0
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
0
1-297

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu230p-2

Table of Contents