p8400[0...2]
RTC time / RTC time
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Sets and displays the time on the real-time clock in hours, minutes, and seconds.
The time is stored in the internal clock block in the drive and continues to run even if the supply voltage for the Con-
trol Unit is interrupted (for approx. 5 days).
Index:
[0] = Hour (0 ... 23)
[1] = Minute (0 ... 59)
[2] = Second (0 ... 59)
Note:
The time from p8400 and p8401 is used to display the fault and alarm times.
The parameter is not reset when the factory setting is restored (p0010 = 30, p0970).
The time is entered and displayed in 24-hour format.
RTC: Real-time clock
p8401[0...2]
RTC date / RTC date
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Sets and displays the date on the real-time clock in year, month, and day.
The date is stored in the internal clock block in the drive and continues to run even if the supply voltage for the Con-
trol Unit is interrupted (for approx. 5 days).
Index:
[0] = Day (1 ... 31)
[1] = Month (1 ... 12)
[2] = Year (YYYY)
Note:
The time from p8400 and p8401 is used to display the fault and alarm times.
The parameter is not reset when the factory setting is restored (p0010 = 30, p0970).
RTC: Real-time clock
r8404
RTC weekday / RTC weekday
Access level: 3
Can be changed: -
Units group: -
Min
1
Description:
Displays the weekday on the real-time clock.
Value:
1:
2:
3:
4:
5:
6:
7:
Note:
RTC: Real-time clock
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Calculated: -
Scaling: -
Unit selection: -
Max
59
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
7
Parameters
List of Parameters
Data type: Unsigned16
Data set: -
Factory setting
0
Data type: Unsigned16
Data set: -
Factory setting
[0] 1
[1] 1
[2] 1970
Data type: Integer16
Data set: -
Factory setting
-
1-339