Siemens SINAMICS G120 Manual page 322

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Parameters
List of Parameters
p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
Access level: 3
Can be changed: U, T
Units group: -
Min
-100000.00 [Nm]
Description:
Sets a fixed value for torque.
Dependency:
Refer to: p2900, p2901
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can, for example, be used to interconnect a supplementary torque.
p3110
External fault 3, power-up delay / Ext fault 3 t_on
Access level: 3
Can be changed: U, T
Units group: -
Min
0 [ms]
Description:
Sets the delay time for external fault 3.
Dependency:
Refer to: p2108, p3111, p3112
Refer to: F07862
p3111[0...n]
BI: External fault 3, enable / Ext fault 3 enab
Access level: 3
Can be changed: U, T
Units group: -
Min
-
Description:
Sets the signal source for the enable signal of external fault 3.
External fault 3 is initiated by the following AND logic operation:
- BI: p2108 negated
- BI: p3111
- BI: p3112 negated
Dependency:
Refer to: p2108, p3110, p3112
Refer to: F07862
p3112[0...n]
BI: External fault 3 enable negated / Ext flt 3 enab neg
Access level: 3
Can be changed: U, T
Units group: -
Min
-
Description:
Sets the signal source for the negated enable signal of external fault 3.
External fault 3 is initiated by the following AND logic operation:
- BI: p2108 negated
- BI: p3111
- BI: p3112 negated
Dependency:
Refer to: p2108, p3110, p3111
Refer to: F07862
1-322
Calculated: -
Scaling: p2003
Unit selection: -
Max
100000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: -
Max
1000 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.00 [Nm]
Data type: Unsigned16
Data set: -
Factory setting
0 [ms]
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
1
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
0