Siemens SINAMICS G120 Manual page 374

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Parameters
List of Parameters
r9463
Set valid macro /
Access level: 3
Can be changed: -
Units group: -
Min
0
Description:
Displays the valid macro.
A value of 0 is displayed if a parameter set by a macro is changed.
p9484
BICO interconnections search signal source / BICO S_src srch
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency:
Refer to: r9485, r9486
r9485
BICO interconnections signal source search count / BICO S_src srchQty
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
Refer to: p9484, r9486
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
r9486
BICO interconnections signal source search first index / BICO S_src srchIdx
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the first index of the signal source being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency:
Refer to: p9484, r9485
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
1-374
Calculated: -
Scaling: -
Unit selection: -
Max
999999
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Data type: Unsigned32
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
0
Data type: Unsigned16
Data set: -
Factory setting
-
Data type: Unsigned16
Data set: -
Factory setting
-
© Siemens AG 2011 All Rights Reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu230p-2