r0060
CO: Speed setpoint before the setpoint filter / n_set before filt.
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the actual speed setpoint at the input of the speed controller or U/f characteristic (after the interpolator).
Dependency:
Refer to: r0020
Note:
The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
r0062
CO: Speed setpoint after the filter / n_set after filter
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the actual speed setpoint after the setpoint filters.
r0063[0...2]
CO: Speed actual value / n_act
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the actual speed of the closed-loop speed control and the U/f control.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
[2] = Calculated from f_set - f_slip
Dependency:
Refer to: r0021, r0022
Note:
The speed actual value r0063[0] is additionally displayed - smoothed with p0045 - in r0063[1].
The speed (r0063[2]) calculated from the output frequency and slip can only be compared with the speed actual
value (r0063[0]) in the steady-state.
r0064
CO: Speed controller system deviation / n_ctrl system dev
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the actual system deviation of the speed controller.
r0065
Slip frequency / f_Slip
Access level: 3
Can be changed: -
Units group: 2_1
Min
- [Hz]
Description:
Displays the slip frequency for induction motors (ASM).
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [Hz]
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
- [Hz]
1-35