p1035[0...n]
BI: Motorized potentiometer setpoint raise / Mop raise
CU230P-2 DP
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to continually increase the setpoint for the motorized potentiometer.
The setpoint change (CO: r1050) depends on the set ramp-up time (p1047) and the duration of the signal that is
present (BI: p1035).
Dependency:
Refer to: p1036
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1036[0...n]
BI: Motorized potentiometer lower setpoint / Mop lower
CU230P-2 CAN
Access level: 3
CU230P-2 HVAC
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to continuously lower the setpoint for the motorized potentiometer.
The setpoint change (CO: r1050) depends on the set ramp-down time (p1048) and the duration of the signal that is
present (BI: p1036).
Dependency:
Refer to: p1035
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1036[0...n]
BI: Motorized potentiometer lower setpoint / Mop lower
CU230P-2 DP
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to continuously lower the setpoint for the motorized potentiometer.
The setpoint change (CO: r1050) depends on the set ramp-down time (p1048) and the duration of the signal that is
present (BI: p1036).
Dependency:
Refer to: p1035
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1037[0...n]
Motorized potentiometer maximum speed / MotP n_max
Access level: 3
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets the maximum speed/velocity for the motorized potentiometer.
Note:
This parameter is automatically pre-assigned in the commissioning phase.
The setpoint output from the motorized potentiometer is limited to this value (see function diagram 3020).
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: p0340 = 1,3,5
Scaling: -
Unit selection: p0505
Max
210000.000 [rpm]
Parameters
List of Parameters
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
[0] 2090.13
[1] 0
[2] 0
[3] 0
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
0
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
[0] 2090.14
[1] 0
[2] 0
[3] 0
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]
1-131