r0047
Motor data ident. routine and speed controller optimization / MotID and n_opt
Access level: 1
Can be changed: -
Units group: -
Min
0
Description:
Displays the actual status for the motor data identification (stationary measurement) and the speed/velocity control-
ler optimization (rotating measurement).
Value:
0:
115:
120:
140:
150:
170:
195:
200:
220:
230:
240:
250:
270:
290:
300:
Note:
Re r0047 = 300:
This value is also displayed if encoder calibration p1990 is selected.
r0050.0...1
CO/BO: Command Data Set CDS effective / CDS effective
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the effective Command Data Set (CDS).
Bit field:
Bit
Signal name
00
CDS eff., bit 0
01
CDS eff., bit 1
Dependency:
Refer to: p0810, p0811, r0836
Note:
The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
r0051.0...1
CO/BO: Drive Data Set DDS effective / DDS effective
Access level: 2
Can be changed: -
Units group: -
Min
-
Description:
Displays the effective Drive Data Set (DDS).
Bit field:
Bit
Signal name
00
DDS eff., bit 0
01
DDS eff., bit 1
Dependency:
Refer to: p0820, p0821, r0837
Note:
When selecting the motor data identification routine and the rotating measurement, the drive data set changeover is
suppressed.
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
No measurement
Measurement q leakage inductance (part 2)
Speed controller optimization (vibration test)
Calculate speed controller setting
Measurement, moment of inertia
Measurement, magnetizing current and saturation characteristic
Measurement q leakage inductance (part 1)
Rotating measurement selected
identification, leakage inductance
Identification, rotor time constant
Identification, stator inductance
Identification, stator inductance LQLD
Identification, stator resistance
Identification, valve lockout time
Stationary measurement selected
Calculated: -
Scaling: -
Unit selection: -
Max
300
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
ON
ON
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
ON
ON
Parameters
List of Parameters
Data type: Integer16
Data set: -
Factory setting
-
Data type: Unsigned8
Data set: -
Factory setting
-
0 signal
OFF
OFF
Data type: Unsigned8
Data set: -
Factory setting
-
0 signal
OFF
OFF
FP
-
-
FP
-
-
1-29