Chapter 31 External Bus

5.Operation of the Ordinary bus interface

5. Operation of the Ordinary bus interface
This section explains operation of the ordinary bus interface.
■ Ordinary Bus Interface
For the ordinary bus interface, two clock cycles are the basic bus cycles for both read access and write access.
The following operational phases of the ordinary bus interface are explained below with the use of a timing chart.
Basic timing (for successive accesses)
WRn + byte control type
Read -> write
Write -> write
Auto-wait cycle
External wait cycle
Synchronous write enable output
CSn delay setting
CSn -> RD/WRn setup, RD/WE -> CSn hold setting
DMA fly-by transfer (I/O -> memory)
DMA fly-by transfer (memory -> I/O)
5.1 Basic Timing
This section shows the basic timing for successive accesses.
■ Basic Timing (For Successive Accesses)
Figure 5-1
"Basic Timing (For Successive Accesses)" shows the operation timing for (TYP3-0 = 0000
0008
)
H
562
, AWR =
B