Fujitsu MB91460 SERIES FR60 User Manual page 538

32-bit microcontroller
Table of Contents

Advertisement

Chapter 31 External Bus
2.External Bus Interface Registers
[Bits 15-12] W15-12 (First Wait Cycle)
These bits set the number of auto-wait cycles to be inserted into the first access cycle of each cycle. Except
for the burst access cycles, only this wait setting is used.
Table 2-5
"Settings for the Number of Auto-Wait Cycles (During First Access)" lists the settings for the number
of auto-wait cycles during first access.
Table 2-5 Settings for the Number of Auto-Wait Cycles (During First Access)
W15
W14
0
0
0
0
1
1
[Bits 11-8] W11-08 (Inpage Access Wait Cycle)
These bits set the number of auto-wait cycles to be inserted into the inpage access cycle during burst access.
They are valid only for burst cycles.
Table 2-6
"Settings for the Number of Auto-Wait Cycles (During Burst Access)" lists the settings for the
number of auto-wait cycles during burst access.
Table 2-6 Settings for the Number of Auto-Wait Cycles (During Burst Access)
W11
W10
0
0
0
0
1
1
If the same value is set for the first access wait cycle and inpage access wait cycle, the access time for the
address in each access cycle is not the same. This is because the inpage access cycle contains an address
output delay.
522
W13
W12
0
0
0
1
...
1
1
W09
W08
0
0
0
1
...
1
1
First access wait cycle
Auto-wait cycle 0
Auto-wait cycle 1
...
Auto-wait cycle 15
Inpage access wait cycle
Auto-wait cycle 0
Auto-wait cycle 1
...
Auto-wait cycle 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr60Mb91460 series

Table of Contents