System Programming
In order to use the 2B Data feature, the Pipeline 25-Px's MLX port must be
programmed for the feature. An extension jack programmed as a QCC position
(Hybrid/PBX mode only) cannot be programmed for 2B data and used by the
access device. Extensions for MFMs (or data communications equipment not
supporting 2B data, such as ISDN terminal adapters) cannot be programmed for
data and should not be connected to 2B data ports.
For programming details, see System Programming.
Platform Requirements
Here is a summary of the required hardware and facilities:
At the MERLIN LEGEND Communications System Release 4.0 or later
control unit:
— A 100D module set up for Primary Rate Interface (PRI) operation or T1
— If a 100D module is used, a CSU (channel service unit) is necessary.
— A 008 MLX or 408 GS/LS MLX module (not firmware vintage 29)
For digital data communications, the system operates with the following
central office switches, according to the access arrangement or facility:
— PRI. Requires Lucent Technologies 4ESS Generic 16 and later; or
If a digital communications device is programmed to have a single Pool
button, two calls to that pool result in a 1B data call. However, if two
separate pools are assigned to the data extension, then a 2B data call
can be established. If there is more than one video system sharing the
pools, 2B data calls can be misrouted.
Privacy is activated automatically for digital data calls.
Digital communications devices cannot receive reminder calls.
Data calls cannot be made into lines programmed for remote access.
Personalized Ringing and Ringing Options have no effect on calls to
digital communications devices. Calls ring immediately.
Personal and System Speed dial codes can be used on digital
communication equipment (DCE).
Data calls cannot be transferred.
Voice Announce to Busy should be disabled at digital data workstations.
Switched 56 operation (with channels programmed for T1 data service);
or an NI-1 BRI line/trunk module for NI-1 BRI service
Lucent Technologies 5ESS Generic 6 and later; or Lucent Technologies
5ESS serving the FTS-2000 network. In Release 5.0 and later systems,
support is included for the NORTEL DMS-100 BCS 36 for local
9
9
Issue 1
June 1997
Page I-75

Advertisement

Table of Contents
loading

Table of Contents