System Renumbering
NOTES:
1. The extension numbers are reserved whether or not adjuncts are
2. If you renumber the extension number of an MLX telephone, the
3. Digital adjuncts that use the system's 2B Data feature use both the
0
1
2
3
4
5
6
7
Main
Pool
70
8
800*
9
*
†
Figure 45.
Renumbering Extensions
Table 40
renumbered and lists their factory settings.
Single Renumbering
Single Renumbering should be used whenever the extension numbers you are
changing to or from are not sequential.
Single Renumbering can be used to assign a specified extension number to the
following: extensions, adjuncts, lines/trunks, telephones, Automatic Route
Selection Access Code, calling groups, Idle Line Access Code, Listed Directory
Number, paging groups, park zones, Pools, and remote access code.
connected to MLX telephones.
system does not automatically change the extension number of the
associated adjunct.
adjunct and the main extension number of an MLX extension jack (see
''Digital Data Calls'' on page 183
Operator Console (not flexible) 0
Extensions
MLX Adjuncts
7100–7299
7300–7499
Lines/Trunks
801–880
ARS Access (Hybrid/PBX mode)/Idle Line Access 9
Listed Directory Number (QCC Queue)
Remote Access
Set Up Space Numbering Plan
gives a brief overview of the extensions that can or cannot be
for more information).
100–199
200–299
300–399
400–499
500–599
600–699
7500–7699 Calling Groups
770–791,
7920–7929
Park
881–888
3 9
Issue 1
June 1997
Page 590
Paging
Groups
793–799
889†
Pools
890–899
3 9