MERLIN LEGEND Communications System Release 5.0
Feature Reference 555-650-110
Features

Basic Rate Interface (BRI)

Basic Rate Interface (BRI)
At a Glance
Users Affected
Reports Affected
Modes
Telephones
System Programming
800 NI-BRI Module
Maximums
BRI modules
Factory Settings
Systemwide Clock
Synchronization Source
Primary Clock
Clock
BRI
Service Profile Identifier
(SPID) assigned to BRI
line
Directory Number (DN)
assigned to BRI line
Timer and counter
thresholds for all BRI
ports in system
T200 Timer
T203 Timer
T303 Timer
T305 Timer
T308 Timer
Telephone users, operators, digital data users
System Information (
Key, Hybrid/PBX
All (display support on MLX telephones only)
Specify 800 NI-BRI modules that provide primary, secondary,
and tertiary clock synchronization and source of clock
synchronization; also activate/deactivate clock:
More
LinesTrunks
Assign telephone numbers (SPID and DN) to BRI lines:
More
LinesTrunks
DN
Enter
Specify BRI timer settings:
More
LinesTrunks
5
Loop (not definable by system manager)
First port in service on an 800 NI-BRI module or first 100D
module in service in control unit
Active
0 digits
0 digits
1000 ms (range 500–5,000 ms, increments of 500 ms)
33 seconds (range 10–255 seconds, increments of 1 second)
4 seconds (range 2–10, increments of 1 second)
30 seconds (range 2–60, increments of 1 second)
4 seconds (range 2–10, increments of 1 second)