E-06" Counter A/B Error; E-07" Cutter Motor Error; E-13" Paper Feed Motor Error; E-14" Fuser Motor Error - KIP 9000 Service Manual

High volume network printer
Table of Contents

Advertisement

7. 1. 3
Service Call Errors
KIP9000 will show the following Service Call Error when it has any significant error which the
service personnel only can fix. (User can not fit these errors.)
Error
Error name
Codes
E-01
Fuser Temperature
Rising Error
E-02
Fuser Over-heating
Error
E-05
Drum Motor Error
E-06
Counter A/B Error
E-07
Cutter Motor Error
E-09
Web End Error
E-13
Paper Feed Motor Error
E-14
Fuser Motor Error
E-16
Wire Cleaning Error
E-21
Fuser Thermostat Error
E-23
LED Head Cleaning
Error
E-26
Surface Potential
Control Error
E-27
Density Sensor Error
E-28
Density Control Error
E-30
Developer
Disconnection Error
E-43
RFID (IC Tag) Error
E-49
Developer Positioning
Motor Error
Error condition
1. Fusing temperature does not rise up to 120
decided time after turning on.
2. Fusing temperature falls down to 70
getting ready.
Fusing temperature is over 200
Drum Motor Control Signal (DRMTR) and Drum Motor
Synchronous Signal (DRMTR_LD) do not synchronize
with each other for a decided time.
1. Counter Control Signal Feed Back (IN_CNT_A or
IN_CNT_B) continues to be L for 1 second or longer
when the Counter should count up.
2. Counter Control Signal Feed Back (IN_CNT_A or
IN_CNT_B) continues to be H for 1 second or longer
when the Counter is not counting up.
1. Cutter remains at its home position although 0.3
seconds has passed since the Cutter Motor has
started the operation.
2. Cutter does not arrive at its home position although
1 second has passed since the Cutter Motor has
started the operation.
3. Home position can not be detected for 2 seconds
during cutter cleaning.
When Web End is detected.
Paper Feed Motor Control Signal (PFMTR) and Paper
Feed Motor Synchronous Signal (PFMTR_LD) do not
synchronize each other for a decided time.
Fuser Motor Control Signal (FUMTR) and Fuser Motor
Synchronous Signal (FUMTR_LD) do not synchronize
each other for a decided time.
Over-current can not be detected although 90 seconds
has passed since the Wire Cleaning Motor had started to
work.
Thermostat is open-circuited.
Over-current can not be detected although 90 seconds
has passed since the LED Cleaning Motor had started to
work.
When the Auto SP Control fails in adjusting the surface
potential to within the acceptable range.
When the initialization of Density Sensor could not be
achieved successfully during Density Lock process.
When the Auto Density Control fails in adjusting the
density to within the acceptable range.
When the connector in Process Unit is disconnected.
When the FRID PCB is defective.
Home position of Developer Unit can not be detected
although 60 seconds has passed since the Developer
Positioning Motor had started the positioning operation.
7-6
o
C within a
o
C after once
o
C.
K115sm7e1.doc

Advertisement

Table of Contents
loading

Table of Contents