KIP 9000 Service Manual page 179

High volume network printer
Table of Contents

Advertisement

6. After re-adjustment, it is necessary to confirm the actual voltage outputted from the "OUTPUT"
Pin on the HVP6.
To confirm it, connect "+" of the multi-meter to "OUTPUT" and "-" to the ground.
Select the DC volt range on the multi-meter.
CN501
7. Select the Function Checking Mode (Sub Mode No.3), and select the Signal Code
"A0" (HV1 : Image Corona Control
NOTE
Do not select the Signal Code "A6" (Grid Bias Control Signal) this time as it outputs only
analog voltage WITHOUT outputting high voltage from "OUTPUT" to the Grid Plate.
Signal Code "A0" (HV1 : Image Corona Control Signal) is suitable for measurement as it
outputs the high voltage to both Image Corona Wire and Grid Plate.
8. Press the [ENTER] Key to output from HVP6.
Measure the voltage with multi-meter.
Press the [ENTER] Key again to stop outputting when measurement is finished.
Standard value of output voltage on "OUTPUT" is -780V +/-20V.
VR1
VR2
Signal).
MENU
MENU
4-81
OUT
PUT
GND
Multi-meter
(DC volt range)
ENTER ONLINE
ENTER ONLINE
K115sm4ea.doc