3. Remove 2 M4x10 screws (5). Also remove 4 M4x14 screws (6) in gray sponges.
NOTE
Gray sponges hold the M4x14 screws (6) and
prevent them from dropping out.
4. Hold the Handles (7) firmly and draw out the Process Unit (8).
Machine
side
8
2-15
5
6
Sponge
M4x14
7