7. 2. 3.15
"E-30" Developer Disconnection Error
Cause
Order
Harness
Main Control PCB
(PW11520)
7. 2. 3.16
"E-43" RFID (IC Tag) Error
Cause
Order
Harness
RFID IC Tag Reader
& WriterPCB
Main Control PCB
(PW11520)
7. 2. 3.17
"E-49" Developer Positioning Motor Error
When "E-49" must not be detected when diagnosing the KIP9000, mask it in the Error Mask Mode.
Its Mask Code is "06". See [8.1.8 Error Mask Mode (Sub Mode 7)] on page 8-114 for the detail.
Cause
Order
Harness
Developer Positioning
Motor (M4)
DC Driver PCB
(PW7755)
Developer Unit
Position Sensor
(PH25)
Main Control PCB
(PW11520)
7. 2. 3.18
"E-F0" Folder Error
Cause
Order
Communication error
Error of Folder
Checking matter
1
Is the connector J84 connected?
(Is another end of this cable
connected to Main Control PCB?))
4
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the harness connected to each
RFID PCB and Main Control
PCB?
3
Can the error be fixed by
replacing the RFID PCB?
4
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the harness connected to the
Developer Positioning Motor?
2
Can the Developer Positioning
Motor (signal code : 68) be
operated properly in the Function
Checking Mode of Service Mode?
3
Can the error be fixed by
replacing the DC Driver PCB?
4
Check the input signal from the
Developer Unit Position Sensor
(signal code 2b) in the
Input/Output Checking Mode of
Service Mode.
Is the status "L" when the
Developer Unit is at the Home
Position and "H" when the unit is
not at the Home Position?
5
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is any error message indicated
on the Operation Panel of
Folder?
2
Is any error message indicated
on the Operation Panel of
Folder?
7-23
Result
Treatment
No
Connect it.
Yes
OK
Result
Treatment
No
Connect it.
Yes
OK
Yes
OK
Result
Treatment
No
Connect it.
No
Replace the Developer Positioning
Motor.
Yes
Reinstall Developer Unit Position
Sensor, Sensor Disc and Cam
correctly.
Yes
OK
No
Replace the Developer Unit Position
Sensor.
Yes
OK
Result
Treatment
No
This is a communication error.
1. Turn off/on both KIP9000 and
folder.
2. Check the cables.
3. Replace the Main Control PCB.
Yes
This is an error of Folder.
Turn off/on the Folder.
If the error still occurs, ask the
service for the Folder.
K115sm7e1.doc