9. If the voltage from HVP6 does not satisfy -780V +/-20V, readjust it to satisfy the requirement.
To adjust the HVP6 voltage, select the Adjustment Mode 0 (Sub Mode No.4) and select the
Item No.1b.
Refer to [8.1.5.3 Operation] on the page 8-36 for how to change the setting value.
Refer to [(21) Current setting for the Grid Plate (No.1b)] on the page 8-63 as for the
contents of the setting.