5. If the voltage from HVP4 does not satisfy the following values, readjust it to satisfy the
requirement.
To adjust the HVP4 voltage, select the Adjustment Mode 0 (Sub Mode No.4) and select the
Item No.1F, 20 and 21.
1F : Separation Corona DC component (PPC)
20 : Separation Corona DC component (Tracing)
21 : Separation Corona DC component (Film)
•
Refer to [8.1.5.3 Operation] on the page 8-36 for how to change the setting value.
•
Refer to [(23) Separation Corona DC component (No.1F to 21)] on the page 8-64 as for
the contents of the setting.