(18) Auto SP Control ON/OFF (No.A2)

Auto SP Control can be set to ON or OFF.
Setting value
Description
OFF
Auto SP Control is not performed.
ON
Auto SP Control is performed.
NOTE
Service Mode 5-A2 is the same setting with User Mode D. When the Auto SP Control is set to
OFF, it may be possible to avoid machine down caused by the service call error E-26. Neither
Service Mode 5-A2 nor User Mode D has setting priority.

(19) Target Surface Potential (No.A3 to A8)

Target Surface Potential at each temperature points (5 degrees step) can be specified, which is
used when the Auto SP Control adjusts the surface potential. The setting range is from 500 to 999
in 1V increment. Increment of the setting value provides a possibility to have bigger density gap
against Developer Bias, which makes the print image lighter.
Item No.
Target setting
A3
Target Surface Potential at 5
A4
Target Surface Potential at 10
A5
Target Surface Potential at 15
A6
Target Surface Potential at 20
A7
Target Surface Potential at 25
A8
Target Surface Potential at 30

(20) Acceptable potential range for Auto SP Control (No.A9)

KIP9000 will show the service call error E-26 if the Automatic SP Control fails in adjusting the
potential to within acceptable range within decided times of trial. The acceptable range can be
specified in the No.A9. The setting value stands for "+/- X volts against the Target Surface
Potential. The setting range is from 4 to 10 volts in 1V increment. Increment of setting value
increases the possibility to avoid service call error E-26.