Name of part
Exit Cover
Interface Connector for
Controller Unit
Interface Connector for
Scanner
Folder Port
SHUT DOWN Port
Diag Port
VGA Port
USB Port
Top Rear Cover
Outlet for Controller Unit
Power Cord
Dehumidify Heater
Switch
Function
Can remove the mis-fed media around Fuser section.
Connects the cable from the controller unit.
D-Sub Connector 36 pins, 3.3Vdc maximum (large)
Connects the cable from the image scanner.
D-Sub Connector 36 pins, 3.3Vdc maximum (large)
Not used in North America
Connects the Shutdown Signal Cable.
KIP 9000 will send a shutdown signal to the controller through this
cable. 12Vdc maximum
Not used usually. (Service personnel may use to make field
service.)
Connect the cable here, which comes from the controller VGA port
by UL-Listed cable for Touch screen LCD. 5Vdc maximum
Connect the cable here, which comes from the controller USB Key
Connector Type B for Touch screen LCD. 5Vdc maximum
Can access the Dehumidify Heater Switch.
In case you place a controller unit outside of the KIP 9000, it is
possible to supply AC power from the KIP 9000 to the controller
unit if you connect the power cord to this outlet. (220 - 240V, 3A
maximum)
Connected controller unit must meet UL Standard 60950-1 (UL-
Listed)
NOTE: Specification for Power Cord used in North America
Use the following type of Power Cord for a controller unit.
(1) Rating
minimum 250VAC 7A
(2) Plug Type
IEC60320: C13
(3) Socket Type
IEC60320: C14
(4) Cord
H05VV-F 3G-0.75mm
SVT3x18AWG
(5) UL-Listed
Connect to the wall outlet alone.
Turns on/off the Dehumidify Heater.
1-8
K115sm1e1.doc