5.13.15 Adjustment of gap between Drum &
NOTE
In case you have replaced or removed the Transfer Guide Plate for some reason, make sure
to check the gap between Drum and Transfer Guide Plate using an exclusive Jig.
And adjust the gap properly if necessary.
The proper gap between Drum and Transfer Guide Plate is
To measure the gap, use the exclusive Jig shown in
the right photo.
Drum Gauge for Transfer Guide (7708560011)
1) Draw out the Process Unit (1) from the machine
making reference to [5.1.1 Drawing out the Process
Unit] on the page 5-3.
0.75mm to 1.25mm
5-223
Transfer Guide Plate
0.75mm to
1.25mm.