2. Enter the Service Mode, select the Special Mode (Sub Mode No.9), and select the Item No.7
(Developer Bias [Positive] Adjustment Mode).
3. Press the [ENTER] Key to output the Positive Developer Bias from BIAS to each roller of
Developer Unit.
Measure the voltage with multi-meter.
Press the [ENTER] Key again to stop outputting when measurement is finished.
Standard value of the Positive Developer Bias to the Toner Supply Roller is -350V +/-3V.
4. If the Positive Developer Bias from BIAS to Toner Supply Roller does not satisfy -350V +/-3V,
readjust it to satisfy the requirement.
To adjust it, rotate the VR7 on the BIAS with a screwdriver.