Fusing Temperature (No.10 To 12); Led Strobe Time (No.13) - KIP 9000 Service Manual

High volume network printer
Table of Contents

Advertisement

(13) Fusing temperature (No.10 to 12)

Fusing temperature for each media type can be changed. The setting unit is "degree centigrade",
and the adjustment range is from 150 to 190.
Item No.
Description
09
Fusing temperature applied when you print with a plain paper.
0A
Fusing temperature applied when you print with a tracing paper.
0b
Fusing temperature applied when you print with a film.
NOTE
Item No.10, 11, and 12 are "dual value items" that are available to set both "Standard Setting
Value" and "Special Setting Value".
Refer to [(10) Standard / Special Setting Value Changing Modes (Items No.09, 0A & 0b)] on
and after the page 8-51 for the detail.

(14) LED strobe time (No.13)

Print density can be adjusted by increasing or decreasing the LED strobe time. The adjustment
unit is "1micro second. The whole print density becomes darker if the value is increased.
NOTE
(1) This setting is applied in the following cases.
Test print
Print from some controller that does not have density setting.
(2) Increment/decrement of this setting evenly affects all Image Enhance Categories.
8-58