(25) Fuser Motor Speed (Bypass feed) (No.27 to 32)

The speed of Fuser Motor can be adjusted. This setting is applied when the print media is fed
from the Bypass Feeder. The adjustment unit is "0.05%", and the adjustment range is from -1.0%
to +1.0%. Increment of the value makes the speed of Fuser Motor faster.
Each Item No. has its own target media type and media size.
Please adjust the proper item.
Item No.
Target media type
27
Plain paper
28
Plain paper
29
Plain paper
2A
Plain paper
2b
Tracing paper
2C
Tracing paper
2d
Tracing paper
2E
Tracing paper
2F
Film
30
Film
31
Film
32
Film
NOTE
(1) Media sizes are classified into 4 levels as follows.
Metric (Width)
Large
A0 and B1
Medium
A1 and B2
Small
A2 and B3
Smallest
A3
(2) Item No.27 to 32 are "dual value items" that are available to set both "Standard Setting
Value" and "Special Setting Value".
Refer to [(10) Standard / Special Setting Value Changing Modes (Items No.09, 0A & 0b)]
on and after the page 8-51 for the detail.
Target media size
Large
Medium
Small
Smallest
Large
Medium
Small
Smallest
Large
Medium
Small
Smallest
Inch (Width)
36", 34" and 30"
24" and 22"
18" and 17"
12" and 11"
8-65