Input From Cut Sheet Size Sensors (05) - KIP 9000 Service Manual

High volume network printer
Table of Contents

Advertisement

(3) Input from Cut Sheet Size Sensors (05)

Input from Cut Sheet Size Sensors is shown by the hexadecimal data.
To check the input situation, convert the hexadecimal into binary. Each of 8 digits of binary data is
related with size sensors as follows.
Example) When "F0" is indicated.
F0
"0" means "Paper is detected", and "1" means "Paper is not detected". In this example
PH31, 32, 33 and 34 detect the paper (ON) while PH35, 36 and 37 do not detect (OFF).
Reference
This mode is available to check if the size sensor is broken or not.
Supposing you check the input condition when an A1S cut sheet media (841mm wide) is
set to the Bypass Feeder, PH35 is suspected to be broken if "90" is indicated as it means
"1 0 0 1 0 0 0 0".
("80" will be indicated if the PH35 is working properly, which means "1 0 0 0 0 0 0 0")
Refer to the explanation on the next page.
MENU
1 1 1 1 0 0 0 0
8-26
ENTER ONLINE
Hexadecimal data
PH31 (Detecting 11")
PH32 (Detecting A4S & 12")
PH33 (Detecting A3S & 17")
PH34 (Detecting 18")
PH35 (Detecting 22")
PH36 (Detecting A2S & 24")
PH37 (Detecting A1S, 30", 34" & 36")
Not used (This is always "1".)
K115sm8e1.doc