5.5.3
Replacing Toner Sensor (Receiver)
1) Remove the Developer Unit (1) from the Process Unit making reference to [5.1.2 Removing
Image Corona, Drum Assembly, Toner Hopper & Developer Unit] on the page 5-6.
1
1
2) Remove 2 M3x5 bind screws (2) to remove the Sensor Bracket (3).
2
3
3) Remove the M3x8 flush head screw (4), and replace the
Toner Sensor
(5) with the new one.
4
5
5-46