KIP 9000 Service Manual page 371

High volume network printer
Table of Contents

Advertisement

5.11.4 Adjustment of gap between Drum &
NOTE
In case you have replaced the Transfer / Separation Corona Unit with the new one, make sure
to check the gap between Drum and Corona Housing 5 using an exclusive Jig.
And adjust the gap properly if necessary.
The proper gap between Drum and Corona Housing 5 is
To measure the gap, use the exclusive Jig shown in
the right photo.
Drum Gauge for Transfer Corona (7708560021)
1) Draw out the Process Unit (1) from the machine
making reference to [5.1.1 Drawing out the Process
Unit] on the page 5-3.
0.4mm to 1.0mm
5-159
Corona Housing 5
0.4mm to
1.0mm.