24) Bring down the Inner Transport Assembly to shorten the Gas Spring Hinges (40), and then bring
up the Gas Spring Jigs (38) to cover the Gas Spring Hinges.
38
NOTE
Gas Spring Hinges will not extend more than required because the Gas Spring Jigs restrict
their extension, so it will be easy to set the hinges when you reassemble.
If you do not use the jigs, hinges will extend fully and it will be very hard to set them again.
25) Pull out each Gas Spring Hinge from the shaft while bringing up the Inner Transport Assembly a
little.
NOTE
Be careful not to make the Gas Spring Hinge come
out from the stopper plate (41) of Gas Spring Jig.
It will be very dangerous because the Gas Spring
Hinge extends momentarily.
40
5-148
41