2. On the other hand, the Auto SP Control calculates the necessary [SP: white] based on the
temperature detected by the Temperature Sensor.
3. The actual surface potential detected by Surface Potential Sensor is compared with the
calculated [SP: white].
4. If the difference between actual potential and required [SP: white] is not within the acceptable
range, the Auto SP Control sets another "Grid Plate Current" and starts from the procedure 1
again. (The acceptable range of surface potential can be specified in the service Mode 5-A9.)
5. The adjustment will be finished if the difference of them comes to be within the acceptable
range. If not within the acceptable range, Auto SP Control will try the above procedures 1 to 4
several times.
6. If the surface potential still can not be adjusted to within the acceptable range even after 6 time
trials, KIP9000 will show the Service Call Error E-26.