KIP 9000 Service Manual page 509

High volume network printer
Table of Contents

Advertisement

7. 2. 3.11
"E-23" LED Head Cleaning Error
When "E-23" must not be detected when diagnosing the KIP9000, mask it in the Error Mask Mode.
Its Mask Code is "0b". See [8.1.8 Error Mask Mode (Sub Mode 7)] on page 8-114 for the detail.
Cause
Order
Harness
LED Cleaning Motor
(M8)
Screw Shaft of LED
Head
DC Driver PCB
(PW7755)
Main Control PCB
(PW11520)
7. 2. 3.12
"E-26" Surface Potential Control Error
Cause
Order
Harness
Image Corona
Or Drum
Surface Potential
Sensor (SPS1)
Main Control PCB
(PW11520)
7. 2. 3.13
"E-27" Density Sensor Error
Cause
Order
Harness
Density Sensor
Or LED Head
Density Sensor
(PH44)
Main Control PCB
(PW11520)
7. 2. 3.14
"E-28" Density Control Error
Cause
Order
Harness
Density Sensor
Or LED Head
Density Sensor
(PH44)
Main Control PCB
(PW11520)
Checking matter
1
Is the harness connected between
LED Cleaning Motor and DC
Driver PCB?
2
Can the LED Cleaning Motor
(signal code : 83) be operated
properly in the Function Checking
Mode of Service Mode?
3
Is the Screw Shaft of LED Head
Dirty or transformed? (In this case
an over load is detected.)
4
Can the error be fixed by
replacing the DC Driver PCB?
5
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the harness connected to
Surface Potential Sensor (SPS1)
and Main Control PCB?
2
Set the Auto SP Control to OFF,
turn off/on the KIP9000, and take
printing. Is any abnormal image
printed, such as "too dark", "with
dark background" and "too light"?
3
Can the error be fixed by
replacing the Surface Potential
Sensor?
4
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the harness connected to the
Density Sensor?
2
Is the Density Sensor or LED
Head dirty with toner?
3
Can the error be fixed by
replacing the Density Sensor?
4
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the harness connected to
Density Sensor and Main Control
PCB?
2
Is the Density Sensor or LED
Head dirty with toner?
3
Can the error be fixed by
replacing the Density Sensor?
4
Can the error be fixed by
replacing the Main Control PCB?
7-22
Result
Treatment
No
Connect it.
No
Replace the LED Cleaning Motor.
Yes
Clean or replace the Screw Shaft.
Yes
OK
Yes
OK
Result
Treatment
No
Connect it.
No
1. Reinstall the Image Corona
correctly.
2. Replace the Drum.
Yes
OK (Set the Auto SP Control back to
ON, and turn off/on the KIP9000.)
Yes
OK (Set the Auto SP Control back to
ON, and turn off/on the KIP9000.)
Result
Treatment
No
Connect it.
No
Clean them.
Yes
OK
Yes
OK
Result
Treatment
No
Connect it.
No
Clean them.
Yes
OK
Yes
OK
K115sm7e1.doc