4. 3. 7. 1

Negative Developer Bias adjustment (Print Cycle)

(1) Negative Developer Bias for Developer Roller
The standard value of Negative Developer Bias outputted to the Developer Roller is -250V +/-3V
against the ground
when the Auto Density Control is set to
Developer Roller
Check and adjust it in the following way.
1. Connect "+" of the multi-meter to "Output 2" on the BIAS and "-" to the ground.
Select the DC volt range on the multi-meter.
VR4 VR3 VR6 VR5
Output 4
CN401
1
Output 3
GND
Multi-meter
(DC volt range)
4-84
OFF.
CN402
CN403
1
1
VR1 VR8 VR7
VR2
Output 2
Output 1
K115sm4ea.doc