4. Press the [ENTER] Key to output from the HVP1.
Measure the voltage with multi-meter.
Press the [ENTER] Key again to stop outputting when measurement is finished.
Standard value of current is -2.0mA +/-0.05mA.
NOTE
If the multimeter shows "2.0V", it means "-2.0mA". (Replace "+" with "-", and replace "V" with
"mA".)
5. If the current from HVP1 does not satisfy -2.0mA +-/0.05mA, readjust it to satisfy the
requirement.
To adjust the HVP1 current, select the Adjustment Mode 0 (Sub Mode No.4) and select the
Item No.1A (Current setting for the Image Corona Wire).
Refer to [8.1.5.3 Operation] on the page 8-36 for how to change the setting value.
Refer to [(20) Current setting for the Image Corona Wire (No.1A)] on the page 8-62 for the
detail of this setting.
CAUTION
Do not adjust the HVP1 current by rotating the VR on HVP1 positively as it is properly
adjusted before shipment!