5. If the current from HVP3 does not satisfy the following values, readjust it to satisfy the
requirement.
To adjust the HVP3 current, select the Adjustment Mode 0 (Sub Mode No.4) and select the
Item No.1C, 1d and 1E.
1C : Current setting for the Transfer Corona Wire (PPC)
1d : Current setting for the Transfer Corona Wire (Tracing)
1E : Current setting for the Transfer Corona Wire (Film)
•
Refer to [8.1.5.3 Operation] on the page 8-36 for how to change the setting value.
•
Refer to [(22) Current setting for the Transfer Corona Wire (No.1C to 1E)] on the page 8-
63 as for the contents of the setting.
CAUTION
Do not adjust the HVP3 current by rotating the VR on HVP3 positively as it is properly
adjusted before shipment!