5.6.2
Replacing Cutter Oil Supply Solenoid (SL2)
1) Remove the Cutter Unit (1) from the machine making reference to [5.6.1 Removing Cutter Unit]
on the page 5-47.
1
2) Remove 2 pieces of bind head screw (2), release the wire from the Mini Clamp (3), and remove
the Stopper (4).
2
NOTE
When you put back the Stopper (4), tighten the
screws (2) pressing the Stopper (4) toward the arrow
mark.
4
3
5-49
1
4
K115sm5e4.doc