4. If the positive Cleaning Roller Bias does not satisfy +800V +-/3V, readjust it to satisfy the
requirement.
To adjust the positive Cleaning Roller Bias, rotate the VR2 on the HVP5 with a screwdriver.
GND
Multi-meter
(DC volt range)
4-78