7. 2
Measures against Errors
7. 2. 1
Measures against Door Open Errors
7. 2. 1. 1
"U-01" Top Roll Deck Open
Cause
Order
Setting condition of
Top Roll Deck
Top Roll Deck
Connector (J70)
Main Control PCB
(PW11520)
7. 2. 1. 2
"U-02" Middle Roll Deck Open
Cause
Order
Setting condition of
Middle Roll Deck
Middle Roll Deck
Connector (J71)
Main Control PCB
(PW11520)
7. 2. 1. 3
"U-03" Bottom Roll Deck Open
Cause
Order
Setting condition of
Bottom Roll Deck
Bottom Roll Deck
Connector (J72)
Main Control PCB
(PW11520)
7. 2. 1. 4
"U-04" Internal Transportation Unit Open
Cause
Order
Setting condition of
Internal Transportation
Unit
Internal Transportation
Unit Sensor (PH24)
Main Control PCB
(PW11520)
Checking matter
1
Is the Top Roll Deck closed
firmly?
2
Is the Connector J70 firmly
connected when Top Roll Deck is
closed?
3
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the Middle Roll Deck closed
firmly?
2
Is the Connector J71 firmly
connected when Top Roll Deck is
closed?
3
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the Bottom Roll Deck closed
firmly?
2
Is the Connector J72 firmly
connected when Top Roll Deck is
closed?
3
Can the error be fixed by
replacing the Main Control PCB?
Checking matter
1
Is the Internal Transportation Unit
closed firmly?
2
Is the light from Photo Interrupter
surely interrupted when the
Internal Transportation Unit is
closed?
3
Can the error be fixed by
replacing the Main Control PCB?
Result
No
Close it firmly.
Yes
Check the connector pin J70-32.
No
Remove the deck and install the
connector (J70) correctly.
Yes
OK
Result
No
Close it firmly.
Yes
Check the connector pin J71-22.
No
Remove the deck and install the
connector (J71) correctly.
Yes
OK
Result
No
Close it firmly.
Yes
Check the connector pin J72-37.
No
Remove the deck and install the
connector (J72) correctly.
Yes
OK
Result
No
Close it firmly. (Confirm the lock
lever is clicked into place.)
No
Reinstall the sensor (PH24)
properly.
Yes
1. Check if the sensor harness is
damaged, or check if the
connector of sensor harness is
surely connected.
2. Replace the sensor (PH24) If the
harness is OK.
Yes
OK
7-8
Treatment
Treatment
Treatment